Wind energyServices
Wind turbine repair and maintenance
From the WINDER archive. The specifications, tariffs, connection rules and statistics in this article may have changed since publication.
Maintenance of wind turbines
Like all equipment, a wind turbine needs servicing. It requires less attention than a car and has no oil, air filters or gaskets to replace, but WINDER still recommends an annual inspection. What does that involve?
First, check that all assemblies are sound and operational. Check the tower cable for twisting and inspect the slip ring if fitted. Where possible, inspect the blades for cracks, especially after a severe storm or a winter in which the blades iced up.
Inspect the turbine head for corrosion and hidden defects. Tighten the hub and flange bolts if necessary.
On a guyed tower, check the tension of the guy wires and tighten them as needed. Test the safety systems, including active high-wind protection and the emergency stop.
On turbines with electronic yaw control, test the yaw system and inspect the anemometer and wind vane.
Checking battery condition is especially important. Systems rated above 5 kW often have large battery banks, and a single failed battery can soon affect the rest of the bank.
We recommend servicing the turbine once a year.
Repair of wind turbines
If you are having problems with an existing turbine and the original installer cannot help, WINDER can take on the diagnosis and repair.
Use the enquiry form on this page and a WINDER engineer will contact you to discuss the fault.