Wind turbines can provide backup and off-grid electricity, heating and hot water. They can also power desalination, water condensation and irrigation equipment. Each application calls for a different equipment layout and operating scheme.

wind turbine as the main power source

The wind turbine can serve as the main source of power supply to a private house or commercial real estate (car station, cellular station), not connected to the power grid.

A charge controller routes electricity from the turbine to a bank of 2 to 180 batteries. These provide a buffer when wind speeds are too low. An inverter converts the battery output (24–480 V DC) into 220/380 V AC for household appliances.

wind turbine as the main power source
  1. Turbine nacelle
  2. Tapered tower
  3. Foundation
  4. Inverter room
  5. Electrical load
  6. Control cabinet
  7. Battery cabinet
  8. Inverter

wind turbine in the backup power supply system

A common arrangement uses a wind turbine for backup power. An automatic transfer switch links the turbine system and the grid. Its switching sequence can be configured for the user’s needs.

This arrangement is most effective where the grid connection has limited capacity or poor power quality.

Wind turbine in the backup power supply system
  1. Turbine nacelle
  2. Tapered tower
  3. Foundation
  4. Inverter room
  5. Electrical load
  6. Control cabinet
  7. Battery cabinet
  8. Inverter
  9. Automatic transfer switch
  10. Transformer substation

Integrated system (wind turbine + solar panels + diesel generator)

Integrated systems come in several configurations, all designed to provide reliable backup power. They can operate on or off the grid.

When the battery charge falls below a preset level, the grid-powered charger switches on. If grid power is unavailable, the diesel generator starts. The load-switching sequence is programmed to suit each site.

Complex system: wind turbine, solar panels, diesel generator
  1. Turbine nacelle
  2. Tapered tower
  3. Foundation
  4. Inverter room
  5. Electrical load
  6. Control cabinet
  7. Battery
  8. Inverter
  9. Automatic transfer switch
  10. Transformer substation
  11. Diesel generator
  12. Solar panels